Technical data |
Designation |
TKTL 10 |
Temperature range using infrared |
–60 to +625 °C (–76 to +1 157 °F) |
Temperature range using probe |
– |
Probe supplied |
– |
Environmental limits |
Operation 0 to 50 °C
(32 to 122 °F)
10 to 95% R.H. |
|
Storage –20 to +65 °C
(–4 to +149 °F)
10 to 95% R.H. |
Full range accuracy
(Tamb=23 ±3 °C) |
Tobj = 0 to 625 °C ±2% of reading or
2 °C (4 °F) whichever is greater
Tobj = –60 to 0 °C
±(2 °C +0,05/degree) |
Response time (90%) |
<1 000 ms |
Display |
LCD |
Displayed resolution |
0,1 °C/F from –9.9~199.9,
otherwise 1 °C/F |
Distance to spot size |
16:1 |
Spectral response |
8–14 μm |
Emissivity |
Pre-set 0,95 |
User selectable backlit display |
No, permanently on |
User selectable laser pointer |
No, permanently on |
Measurement modes |
Max temperature |
Alarm modes |
– |
Laser wavelength |
635–650 nm |
Laser |
Class 2 |
Maximum laser power |
1 mW |
Dimensions |
195 x 70 x 48 mm
(7.7 x 2.7 x 1.9 in) |
Packaging |
Carton box |
Case dimensions |
– |
Weight |
230 g (0.5 lbs) |
Battery |
2 x AAA Alkaline type IEC LR03 |
Battery lifetime |
18 hours |
Switch off |
Automatic after 15 s after trigger
is released |
EMC standards |
EN 61326-1,-2-2:2006 |
Laser standards |
21CFR, Ch 1-J |